Error handling
Runtime fault visualization for the connected robot (Go2 and G1) — surfaces firmware-reported faults the moment they appear, keeps an authoritative active set in memory, and exposes three ways to view them: a NavBar badge, a click-anchored popover, and a full-screen Errors page (also reachable from the Hub).
Wire protocol
Faults arrive on the WebRTC data channel, not on a topic. Three message
types share one payload shape — an array of triples
[timestamp, error_source, error_code]:
type |
Direction | data |
Meaning |
|---|---|---|---|
errors |
Robot → app | [[ts, src, code], …] |
Authoritative snapshot of every fault currently active. Sent periodically and immediately after validation. |
add_error |
Robot → app | [ts, src, code] (single triple) |
A new fault just appeared. |
rm_error |
Robot → app | [ts, src, code] (single triple) |
An existing fault just cleared. |
Field types:
timestamp— unix seconds (integer). The "appeared at" time of the fault.error_source— integer category, see the source table.error_code— single bit value. One active fault per entry — never packed bitmasks. Multiple simultaneous faults in the same source arrive as multiple triples. Go2 codes stay inside 9 bits (max0x100); G1 widens the field to 28+ bits (max0x10000000seen) — still well insideNumber.MAX_SAFE_INTEGER, so noBigInthandling is needed.
A typical first errors message after validation looks like:
{
"type": "errors",
"data": [
[1715890123, 300, 16],
[1715890145, 200, 1]
]
}
Decoded: "Winding overheating (motor)" since 21s ago, and "Rear left fan jammed" since just now.
Reconciliation model
The store treats errors as the source of truth and add_error / rm_error
as deltas that keep the UI in lock-step between snapshots:
errors→replaceAll(triples). Existing entries keep their original timestamp so the "appeared at" label doesn't jitter on resync.add_error→ insert. No-op if the(source, code)key already exists, so a snapshot/delta race during reconnect doesn't double-fire.rm_error→ remove by(source, code). No-op if not present.- WebRTC disconnect → store is cleared.
This lets the UI react in real time (a new fault toasts the instant the firmware detects it) without ever drifting indefinitely — the next snapshot resyncs the full active set.
UI surfaces
| Surface | Where | Behavior |
|---|---|---|
| Toast | Bottom-right, floating | Slides in on every add_error. Snapshot replays are silent so reconnects don't spam. 4.5s auto-dismiss; click to dismiss early. |
| NavBar badge | Top-right of the Control screen | Red warning triangle + count chip. Visible only when active count > 0. Click opens the popover. |
| Floating badge | Top-right on Hub / Status / Services / Account / BT screens | Same icon + count, anchored as a persistent floating icon. Hidden on the Control screen (the NavBar badge takes over). |
| Popover | Anchored under whichever badge was clicked | Header with active count, up to four rows visible, scroll for more. Shows code label · source · code id · relative time. Closes on outside-click or when the active set empties. |
| Errors page | Reached via the Hub's Errors button | Full-screen grouped view. Faults are bucketed by source category with a section header. Each row shows the code label, a hex 0x… chip with the bit value, and a two-line time stack (absolute clock + relative). |
Sources
| ID | Family | Label | Notes |
|---|---|---|---|
| 100 | Go2 / G1 | Communication firmware error | DDS, distribution switch, MCU, motor link, battery I²C |
| 200 | Go2 / G1 | Communication firmware error | Cooling fans (front / rear-left / rear-right) |
| 300 | Go2 / G1 | Motor malfunction | Overcurrent / overvoltage / encoder / thermals |
| 301–399 | G1 | Motor N (= source − 300) | Same code semantics as 300, attributed to one joint |
| 400 | Go2 / G1 | Radar malfunction | LiDAR motor, point-cloud integrity, serial port, dirt |
| 500 | Go2 / G1 | UWB malfunction | Serial open, info retrieval |
| 600 | Go2 / G1 | Motion Control | Software thermal + low-battery protections |
| 700 | Go2 / G1 | BMS error | Battery management faults |
| 800 | G1 | Chassis error | Humanoid-specific physical fault |
| 900 | G1 | Power distribution switch anomaly | Power-rail fault (source label only — no code labels shipped) |
| 1000 | G1 | Emergency Stop | E-stop triggered |
| 3000–3999 | G1 | Motor N (= source mod 100) | Alternate per-joint addressing — same 300 code bits |
Per-motor synthesis
G1 reports per-joint motor faults using two source-number conventions:
301 + jointIdx and 3000 + jointIdx. Both ranges are resolved at lookup
time by lookupSource() — they return
"Motor N" and share source 300's code-bit catalog via
lookupCode(), so the same overcurrent
/ encoder / overheat bits decode correctly whether the fault is attributed
generically (source 300) or to a specific joint.
Sample codes
Codes are looked up by (source, hex(code)). A few representative entries:
| Source | Code (decimal / hex) | Family | Label |
|---|---|---|---|
| 100 | 1 / 0x1 |
Go2 / G1 | DDS message timeout |
| 100 | 16 / 0x10 |
Go2 / G1 | Battery communication error |
| 100 | 128 / 0x80 |
Go2 / G1 | Motor communication error |
| 200 | 1 / 0x1 |
Go2 / G1 | Rear left fan jammed |
| 200 | 4 / 0x4 |
Go2 / G1 | Front fan jammed |
| 300 | 1 / 0x1 |
Go2 / G1 | Overcurrent |
| 300 | 4 / 0x4 |
Go2 / G1 | Driver overheating |
| 300 | 16 / 0x10 |
Go2 / G1 | Winding overheating |
| 300 | 32 / 0x20 |
Go2 / G1 | Encoder abnormal |
| 300 | 256 / 0x100 |
Go2 / G1 | Motor communication interruption |
| 300 | 4 096 / 0x1000 |
G1 | Command anomaly |
| 300 | 65 536 / 0x10000 |
G1 | Status anomaly |
| 300 | 16 777 216 / 0x1000000 |
G1 | Motor humidity anomaly |
| 300 | 33 554 432 / 0x2000000 |
G1 | Encoder remote |
| 300 | 67 108 864 / 0x4000000 |
G1 | MOS almost overheat |
| 300 | 134 217 728 / 0x8000000 |
G1 | Encoder close |
| 300 | 268 435 456 / 0x10000000 |
G1 | Winding almost overheat |
| 400 | 1 / 0x1 |
Go2 / G1 | Motor rotate speed abnormal |
| 400 | 2 / 0x2 |
Go2 / G1 | PointCloud data abnormal |
| 400 | 16 / 0x10 |
Go2 / G1 | Abnormal dirt index |
| 500 | 1 / 0x1 |
Go2 / G1 | UWB serial port open abnormal |
| 600 | 4 / 0x4 |
Go2 / G1 | Overheating software protection |
| 600 | 8 / 0x8 |
Go2 / G1 | Low battery software protection |
Unknown (source, code) pairs fall back to Source <id> and Code 0x<hex> so
the UI keeps working when the firmware introduces a new fault.
Where this lives in the source
src/protocol/errors-catalog.ts— source/code label tables +decodeError()helper.src/protocol/error-store.ts— observable active-set, reconciliation rules.src/protocol/data-channel.ts— wire dispatcher (errors/add_error/rm_error→ store).src/ui/components/errors-badge.ts— badge (inline + floating flavours).src/ui/components/errors-popover.ts— anchored dropdown.src/ui/components/errors-page.ts— grouped full-screen view.src/ui/components/error-toast.ts— transient new-fault notification.
Adding a new code
When the firmware ships a new fault bit, add the label to CODE_LABELS in
errors-catalog.ts using the key
<source>_<lowercase-hex-code> (no 0x prefix, no padding) — for example